Rubber-Backed Ceramic Transfer Point Liner

Rubber-Backed Ceramic Transfer Point Liner

Rubber-Backed Ceramic Transfer Point Liner combines a dense alumina ceramic wear layer with a resilient rubber backing for transfer points exposed to impact and abrasive material flow.
Send Inquiry
Product Introduction

Rubber-Backed Ceramic Transfer Point Liner combines a dense alumina ceramic wear layer with a resilient rubber backing for transfer points exposed to impact and abrasive material flow. The composite structure is designed for conveyor chutes, hoppers, loading zones and discharge sections where sliding wear and material impact occur together.

 

Product Structure

 

Alumina Ceramic Working Layer
The working surface uses 92% or 95% alumina ceramic. Its high hardness provides a wear-resistant surface for continuous contact with abrasive bulk materials.


Rubber Backing
The rubber layer supports the ceramic from below and absorbs part of the impact energy. Rubber hardness and thickness are selected according to material size, drop conditions and mounting requirements.

 

Why This Liner Fits Transfer Points

 

Abrasion and Impact Resistance
The ceramic surface handles sliding abrasion from bulk material, while the elastic rubber layer helps cushion impact loads transmitted through the ceramic tiles.


Hot-Vulcanized Bond
Ceramic elements are integrated into the rubber backing through hot vulcanization. This creates a unified composite panel with consistent contact between the ceramic and supporting layer.


Modular Replacement
Panel construction allows worn sections to be replaced by defined areas. Standard panel sizes also simplify layout planning for chute walls, hoppers and transfer zones.

 

Typical Technical Parameters

 

Parameter

Typical Value

Alumina Content

92% / 95%

Ceramic Bulk Density

≥ 3.60 g/cm³

Ceramic Hardness

Mohs 9

Ceramic Thickness

6–50 mm

Rubber Hardness

45–65 Shore A

Rubber Tensile Strength

≥ 14 MPa

Rubber Elongation

≥ 250%

Rubber Thickness

4–10 mm

Standard Panel Sizes

200 × 200 mm / 300 × 300 mm / 500 × 500 mm

Total Panel Thickness

12–65 mm

 

Size and Thickness Selection

 

Ceramic Thickness
Ceramic thickness is selected according to particle size, drop height and impact intensity. Thicker ceramic sections are suitable for zones receiving larger particles or concentrated material flow.


Rubber Thickness
A 4–10 mm rubber backing provides the elastic support required beneath the ceramic layer. The selected thickness depends on impact conditions and panel construction.


Panel Dimensions
Standard panels are available in 200 × 200 mm, 300 × 300 mm and 500 × 500 mm formats. Custom dimensions can be configured for equipment geometry and installation layout.

 

Installation Options

 

Adhesive Bonding
Panels with a prepared rubber bonding surface can be installed on clean steel substrates using a suitable structural adhesive. The steel surface should be properly prepared before installation.


Mechanical Fixing
For mechanically secured applications, composite panels can incorporate a steel backing plate with countersunk bolt holes. This configuration provides direct fastening to the equipment structure.

 

Application Areas

Conveyor Transfer Chutes

Installed on chute walls, impact zones and deflection surfaces exposed to repeated material contact and sliding abrasion.

Hoppers and Loading Zones

Used beneath feed points where bulk material changes from vertical impact to horizontal or inclined flow.

Discharge Sections

Applied around discharge interfaces where changes in material direction create concentrated wear along defined flow paths.

 

Material and Operating Conditions

 

Material Size and Drop Height
Particle size and vertical drop height directly affect impact loading. These conditions should be considered when determining ceramic and rubber thickness.


Temperature and Moisture
Operating temperature and moisture conditions affect rubber compound selection and adhesive requirements. These values should be provided during product configuration.


Flow Pattern
The liner layout should follow the actual material trajectory. High-contact areas can receive thicker or more impact-resistant panel configurations.

 

Inspection and Quality Control

 

Ceramic Inspection
Ceramic components are checked for alumina content, density, hardness, dimensions and visible surface defects before composite assembly.


Composite Bond Inspection
The vulcanized interface is inspected for bonding integrity and panel thickness. Finished panels are checked against the specified dimensions before packing.

 

Information Required for Selection

Equipment Data

Provide equipment drawings, lining dimensions, available clearance and the required fixing method.

Material Data

Specify material type, maximum particle size, bulk density and moisture condition.

Operating Data

Provide drop height, material flow rate, operating temperature and the expected wear conditions for the lining area.

 

Packaging and Replacement Planning

 

Panel Protection
Panels are separated and secured during packing to protect ceramic edges, working surfaces and rubber backing during handling and transport.


Project Quantities
Panels can be grouped according to equipment section, panel size and installation sequence to simplify site identification.


Replacement Identification
Replacement panels can be identified by ceramic grade, ceramic thickness, rubber thickness, panel dimensions and mounting position.

 

FAQ

 

Q: What is a rubber-backed ceramic transfer point liner?

A: It is a composite wear panel consisting of an alumina ceramic working layer and a resilient rubber backing. The ceramic provides abrasion protection while the rubber supports the ceramic under impact.

Q: Which alumina grades are available?

A: The standard ceramic options are 92% and 95% alumina. Grade selection depends on the required wear and impact conditions.

Q: How is ceramic thickness selected?

A: Ceramic thickness is selected according to particle size, drop height and impact intensity. Typical ceramic thickness ranges from 6 mm to 50 mm.

Q: What rubber thickness is available?

A: Typical rubber backing thickness ranges from 4 mm to 10 mm. The selected thickness depends on the impact load and composite panel design.

Q: Can the liner be mechanically fixed?

A: Yes. Composite panels can be supplied with an embedded steel backing plate and countersunk bolt holes for mechanical fastening where the equipment structure requires bolted installation.

Hot Tags: rubber-backed ceramic transfer point liner, China rubber-backed ceramic transfer point liner manufacturers, suppliers, factory

Send Inquiry

Home

Phone

E-mail

Inquiry